NACE-CIP2-001 exam is designed to assess the knowledge and skills of professionals involved in the inspection and evaluation of coating systems. Coating Inspector Level 2 certification program covers a range of topics, including surface preparation, coating application, coating inspection, and testing of coatings. Upon successful completion of the exam, professionals are certified as Coating Inspector Level 2, which signifies their ability to perform detailed inspection and evaluation of coating systems in accordance with industry standards and best practices. Coating Inspector Level 2 certification is highly valued and recognized by industry professionals worldwide, making it an essential credential for those seeking to advance their careers in the coating inspection industry.

 

NO.35 Which surface preparation method uses a dilute acid solution to remove laitance and I roughen the concrete surface?

 
 
 
 

NO.36 Linings are used on the interior of pipelines to

 
 
 
 

NO.37 Examples of non-ferrous metals include
Select All that Apply:

 
 
 
 

NO.38 When performing an adhesion test in accordance with ASTM D 3359 where the Dry Film Thickness is approximately 10 mils, the Inspector should use:

 
 
 
 

NO.39 NACE International Standards are developed by:

 
 
 
 

NO.40 Which product, is used in conjunction with other coatings such as FBE when the lines run through wetlands or a body of water?

 
 
 
 

NO.41 You are the NACE Inspector on a project where a stationary floating structure is being coated and you notice a self-smoothing anti-fouling coating has been specified.
This is not a good choice because:

 
 
 
 

NO.42 Inspectors perform tests on linings that they may not perform on exterior coatings because

 
 
 
 

NO.43 The Inspectors’ goal at the Pre-Job Conference is to:

 
 
 
 

NO.44 Because a NACE Level 2 Inspector has been trained in specific destructive tests, it is up to the Inspector to decide if and when a destructive test is required.

 
 

NO.45 Inspection and Test Plans are provided to:

 
 
 
 

NO.46 In powder coatings, when the particles of powder begin to flow but are not fully liquid, they are in what stage?

 
 
 
 

NO.47 You are a NACE Level 2 in-house inspector working in a shop. Your in-house requires you to perform a sleeve test to test for soluble salts; however the 3 rd party NACE Level 3 inspector, the owner, has a san smart meter and has achieved a very different result and has rejected the pre-cleaning.
Your FIRST course of action is to:

 
 
 
 

NO.48 It is always possible to see moisture on a steel substrate:

 
 

NO.49 Non-Conformance Reports are designed to:

 
 
 
 

NO.50 Corrosion is the reverse process of

 
 
 
 

NO.51 You are NACE Level 2 Inspector working on a tank lining job where a mobile centrifugal blast unit is being used to blast the tank floor to a NACE No.1/SSPC SP 5. The Contractor has completed his final blast and has called for a hold point inspection. This is the 1 st time you have seen field based centrifugal blast cleaning. You observe what appears to be staining on the substrate however the Contractor assures you this is normal when using centrifugal blast units and what you are seeing is what is defined in the standard as an acceptable variation in appearance.
Your FIRST preferred course of action is to:

 
 
 
 

NO.52 You are the NACE Level 2 Coating Inspector where SSPC PA 2 has been specified with an additional requirement that no individual gauge reading shall be below a certain value.
As this is not part of the standard you should:

 
 
 
 

NO.53 When conducting inspections the Inspector should follow which standards:

 
 
 
 

NO.54 You are the NACE Coating Inspector on a tank lining project and are asked to perform a high voltage holiday test after the coating applicators have completed their final repairs. After meeting all the confined space entry permit you enter the tank and notice a very strong odor of solvent.
Your first course of action should to:

 
 
 
 

NO.55 The primary purpose of Fireproofing coatings are to provide:

 
 
 
 

NO.56 You are the NACE Level 2 Inspector on a project where overcoating of galvanized steel is being performed. The specification references SSPC SP 16 as the surface preparation method. At the pre-job meeting operations personnel make it clear that abrasive blasting will not permitted. The Owner’s representative asks you what other methods might be used.
Of the options shown below, what would be the preferred option in this situation?

 
 
 
 

NO.57 Coating application to concrete substrates is:

 
 
 
 